ITW EAE Support Center

9-273976 Protocol Plus to Protocol 3 Kit Instructions

See attached file for a PDF version of the instructions below.

  1. Before removing the Protocol Plus from the oven, record what wire are connected to each of the terminals on the back of the Protocol Plus control.
  2. Unplug the wiring from the back of the Protocol Plus control, and remove the control from the oven control panel.
  3. Install the new Protocol3 control into the oven cabinet.
  4. Connect the terminal blocks to the Protocol 3 as indicated in the table below.

Terminal Block

Protocol Plus Connections

Protocol 3 Connections

Three pin terminal block for power

Terminals 30, 31, 32

Terminals 1, 2, 3

Five pin terminal block for SSR and Hi-limit

Terminals 17, 18, 19, 20, 21

Terminals 26, 27, 28, 29, 30

Thermocouple connections

Remove the four pin terminal block from thermocouple wires, and rewire with the two three pin blocks provided with kit

Control Thermocouple Terminals 13, 14

Control Thermocouple Terminals 17, 18. Red wire on 18

Hi-limit Thermocouple Terminals 15, 16

Hi-Limit Thermocouple Terminals 32, 33. Red wire on 33

Relay Outputs

Terminals 22, 23, 24, 25, 26, 27, 28, 29

Terminals 4, 5, 6, 7, 8, 9, 10, 11

Process Out

Terminals 11, 12

Terminals 14, 15

Digital Inputs

Terminals 6, 7, 8, 9, 10

Terminals 22, 23, 24, 25, 21

Digital Comm

Terminals 1, 2, 3, 4, 5

Consult Factory if used

 

A close up of a label

AI-generated content may be incorrect.

  Protocol Plus Rear Panel

 

A white label with black text

AI-generated content may be incorrect.

Protocol 3 Rear Panel

 

Note: Your new Protocol3 controller needs to be configured with the enclosed USB Stick.

The USB Stick contains the following files:

Read Me File

Protocol 3 Owners Manual

Operator Training PowerPoint show

Sample Profile file

Oven Configuration files (LAC, LCC, LCC-N, LCD, LCD-N, LBB, LAD, LFD, LND, LXD, PTC, T-D, R-D,   GAS-500, GAS-650,)

To load configuration into control:

 

  1. Insert USB memory stick into Protocol 3 control
  2. Press Description: ForwardButton-09202011 copy.jpg to display Mode Unlock Code screen.
  3. Press Description: UpButton-09202011 copy.jpg as necessary to enter Factory Unlock Code 0010.
  4. Press Description: ForwardButton-09202011 copy.jpg  to display the USB Menu screen.
  5. Press DownButton-09202011 copy.jpg to select Read Configuration File.
  6. Press Description: ForwardButton-09202011 copy.jpg  to display Select File screen.
  7. Press Description: UpButton-09202011 copy.jpg or DownButton-09202011 copy.jpg to highlight the file name that corresponds with the model number of your oven.
  8. Press Description: ForwardButton-09202011 copy.jpg  to display Confirm Read?
  9. Press DownButton-09202011 copy.jpg to select Yes.
  10. Press Description: ForwardButton-09202011 copy.jpg to read configuration file into the control.
  11. Press Description: ForwardButton-09202011 copy.jpg
  12. Press Description: UpButton-09202011 copy.jpg and Description: ForwardButton-09202011 copy.jpg at the same time twice to exit to the Select a Mode screen.
  13. Remove USB memory stick.

 

Your control is now configured for your model oven.

Visit out Support Center for more Tutorials & Documentation on the Protocol 3 control.

See the link below.

https://support.itweae.com/support/search?term=Protocol+3

 

D
Dan is the author of this solution article.

Did you find it helpful? Yes No

Send feedback
Sorry we couldn't be helpful. Help us improve this article with your feedback.