See attached file for a PDF version of the instructions below.
- Before removing the Protocol Plus from the oven, record what wire are connected to each of the terminals on the back of the Protocol Plus control.
- Unplug the wiring from the back of the Protocol Plus control, and remove the control from the oven control panel.
- Install the new Protocol3 control into the oven cabinet.
- Connect the terminal blocks to the Protocol 3 as indicated in the table below.
Terminal Block | Protocol Plus Connections | Protocol 3 Connections |
Three pin terminal block for power | Terminals 30, 31, 32 | Terminals 1, 2, 3 |
Five pin terminal block for SSR and Hi-limit | Terminals 17, 18, 19, 20, 21 | Terminals 26, 27, 28, 29, 30 |
Thermocouple connections Remove the four pin terminal block from thermocouple wires, and rewire with the two three pin blocks provided with kit | Control Thermocouple Terminals 13, 14 | Control Thermocouple Terminals 17, 18. Red wire on 18 |
Hi-limit Thermocouple Terminals 15, 16 | Hi-Limit Thermocouple Terminals 32, 33. Red wire on 33 | |
Relay Outputs | Terminals 22, 23, 24, 25, 26, 27, 28, 29 | Terminals 4, 5, 6, 7, 8, 9, 10, 11 |
Process Out | Terminals 11, 12 | Terminals 14, 15 |
Digital Inputs | Terminals 6, 7, 8, 9, 10 | Terminals 22, 23, 24, 25, 21 |
Digital Comm | Terminals 1, 2, 3, 4, 5 | Consult Factory if used |
Protocol Plus Rear Panel
Protocol 3 Rear Panel
Note: Your new Protocol3 controller needs to be configured with the enclosed USB Stick.
The USB Stick contains the following files:
Read Me File
Protocol 3 Owners Manual
Operator Training PowerPoint show
Sample Profile file
Oven Configuration files (LAC, LCC, LCC-N, LCD, LCD-N, LBB, LAD, LFD, LND, LXD, PTC, T-D, R-D, GAS-500, GAS-650,)
To load configuration into control:
- Insert USB memory stick into Protocol 3 control
- Press
to display Mode Unlock Code screen.
- Press
as necessary to enter Factory Unlock Code 0010.
- Press
to display the USB Menu screen.
- Press
to select Read Configuration File.
- Press
to display Select File screen.
- Press
or
to highlight the file name that corresponds with the model number of your oven.
- Press
to display Confirm Read?
- Press
to select Yes.
- Press
to read configuration file into the control.
- Press
- Press
and
at the same time twice to exit to the Select a Mode screen.
- Remove USB memory stick.
Your control is now configured for your model oven.
Visit out Support Center for more Tutorials & Documentation on the Protocol 3 control.
See the link below.
https://support.itweae.com/support/search?term=Protocol+3