See link below for the LE4SA Process Timer Basic Operations video.
When the process timer is powered on your timer will start.
When your set time has finished, the number "one" will display, indicating that your output contacts have energized.
The "Reset" key will restart your process timer.
To adjust your set time, start by pressing the “left arrow” key. Use the “up” key to make your adjustment. Press the “left arrow” key to move to the next digit.
When you are finished making adjustments, press the “mode” key.
To enter the “Function Setting Mode”, press and hold the “mode” key for 3 seconds.
The output operation mode will display. “OND” is the default setting and indicates that timed output will start when the control is powered on.
Press the “mode” key once to progress.
Next is the “Time Range” parameter. Here you can change the format of your timer. The default setting is 99.99 seconds.
Press the “mode” key to display the “Time Progress” setting. Here you can change your timer to count up or down. The default setting is “up”.
Next is the “output contacts” parameter. The default setting is 1C.1C.
Press the “mode” key to display the backlight settings parameter. Here you can turn the backlight on or off.
Lastly, we will see the “Key Lock Selection” parameter. Here you can lock or unlock different keys. The default selection is LOC.1.
To return to the timer screen, press and hold the “Mode” key for 3 seconds.